An electric truck has no alternator. The SAGMOTO i5, with a 120 to 160 kW permanent magnet motor and a 100 to 140 kWh traction battery, makes high voltage and nothing else. Every 24 volt load, from wipers and headlamps to brake lights, CAN gateway, BMS controller and dashboard, runs from a small 24 volt auxiliary battery kept charged by a DC-DC converter drawing on the traction pack.
That makes the converter one of the most important parts on the vehicle and the least understood by technicians trained on diesels. When it fails the truck can have a full traction battery and still refuse to move, because half the control system runs on 24 volts. This guide covers how the auxiliary system works, how to diagnose low-voltage faults in order, and what the converter and battery need over a working life.
How the i5 Auxiliary Power System Is Laid Out
Four parts sit in series: traction battery, DC-DC converter, 24 volt auxiliary battery and loads. The traction pack is isolated from the chassis. The converter steps it down to a regulated 27 to 28.5 volts, running the loads and charging the auxiliary battery, which supplies contactor-closing current, buffers voltage dips from large loads and keeps the electronics alive when the converter is off.
The converter runs only when the vehicle calls for it, typically with the key on or while the high-voltage system is awake for charging, plus a periodic conditioning cycle that tops the auxiliary battery while parked. That is why an i5 can sit for weeks and still wake, where a diesel would need a jump start.
A dead 24 volt auxiliary battery is not automatically a battery fault. On an electric truck it is usually the last visible symptom of a converter that has stopped outputting, of a sleep-state logic error that prevented the conditioning cycle, or of parasitic drain from an aftermarket device. Replace the converter first and the battery second, never the reverse.
What the Converter Does and What It Cannot Do
The converter is a switching supply that holds output flat at about 27.5 volts from zero load to rated current, then tapers and allows voltage to sag rather than overheat. Rating on an i5 is typically 2.5 to 3 kW, enough for lighting, HVAC blower, wipers and electronics with margin to recharge the auxiliary battery.
What it cannot do is feed a sustained load beyond its rating. A 24 volt air conditioner, a high-power radio or a large work-light array will pull the rail down on every switch-on, and the resulting under-voltage faults get blamed on the converter. Add up every load before fitting one more accessory.
| Parameter | Typical i5 value | What out-of-range means |
|---|---|---|
| Nominal output voltage | 27.0-28.5 V | Below 26 V at idle means converter or battery fault |
| Output current rating | 2.5-3.0 kW class | Constant current limiting means over-capacity loads fitted |
| Efficiency | 92-95 percent | Converter case hot well beyond normal is a sign of internal fault |
| Input voltage range | Traction pack nominal | Converter shuts down outside range for protection |
| Auxiliary battery | 2 x 12 V in series, 24 V nominal | Resting voltage below 24.0 V indicates a discharged or failed battery |
| Standby drain | Under 50 mA | Higher drain flattens battery during long parking |
Diagnostic Order for Low-Voltage Faults
The most common diagnostic mistake on an i5 is starting with the battery. Fit a new one, and the truck works for a few days before failing again, because the battery was only the symptom. Work in this order instead.
Step 1: Read the fault codes before touching anything
Pull codes from the vehicle controller and, where it reports separately, the converter module. Under-voltage codes at key-on or converter communication loss point straight at the DC-DC unit. A cluster of unrelated modules going offline points at the 24 volt rail collapsing. Write codes down before clearing, because their order usually tells the story.
Step 2: Measure the rail at three points
Measure 24 volt output at the converter terminals, at the battery posts and at a distant load point such as a headlamp connector. Awake, the converter should read near 27.5 volts. Converter at 27.5 with the battery at 24.5 means cable resistance or a blown in-line fuse. Both low means the converter is not regulating. Battery high but load point low means a bad ground or corroded joint.
Step 3: Load test the auxiliary battery properly
A lead-acid battery looks healthy on a voltmeter until a load is applied. Test under load, with a proper tester or by switching on the headlamps and watching for 30 seconds. Collapsing from 25 volts to below 22 under 50 amps means the battery is finished, and it finished for a reason: age, chronic discharge or overcharge.
| Symptom | Probable cause | Verification | Repair |
|---|---|---|---|
| Truck will not wake, traction battery full | Auxiliary battery flat or converter asleep | Measure 24 V rail, read sleep-state codes | Charge or replace battery, cycle wake sequence |
| Battery flat after two or three days parked | Parasitic drain or failed conditioning cycle | Clamp meter on battery negative, measure drain | Find and remove drain, check converter wake logic |
| Headlamps dim, warning lamps flicker | Converter not regulating, load above rating | Voltage at converter output under load | Replace converter, audit fitted loads |
| 24 V rail at 30 V or higher | Converter regulation failure, overcharge risk | Voltage measurement at battery posts | Stop use, replace converter before battery boils |
| Battery bulging or hot | Overcharge from faulty converter | Temperature and voltage check | Replace converter and battery together |
| Intermittent module offline codes | Poor ground or cable resistance in 24 V path | Voltage drop test across cable and chassis ground | Clean and tighten terminals, replace corroded cable |
| Converter case very hot to touch | Internal failure or cooling air blocked | Inspect cooling path, check fan operation | Clear cooling path, replace if still hot at no load |
Isolation and Safety on the High-Voltage Side
Never open the converter with the traction system live. Its input sits at pack voltage, which is lethal, and the internal capacitors hold charge long after de-energising. Follow the isolation procedure exactly: switch off, remove the service disconnect, wait the specified time, then confirm zero volts at the converter input with a meter rated for pack voltage before touching anything.
Use insulated tools and a proper high-voltage glove kit. A small light truck does not mean small voltage; the pack is high on any build and the converter sits directly on it. When replacing a converter, label the cable ends, photograph the connector layout and refit in the same position, because mis-routing a high-voltage cable creates a chafing point against the frame.
Battery Management and Charging Behaviour
The auxiliary battery works harder than a diesel starting battery. It never sees alternator charge current, so sulfation builds slowly, but it sits at partial charge for long periods because the conditioning cycle runs only in a set window. Managing that state is part of the maintenance programme.
Check battery open-circuit voltage monthly after an overnight park. Healthy is 25.2 to 25.8 volts; below 25.0 means partial discharge and below 24.5 a failing cell. Check terminal torque and cleanliness every three months, since a loose terminal causes the same intermittent faults as on any vehicle. Check the converter cooling path every 10,000 km, roughly three months on urban delivery, because dust and packaging debris blocking the fins make the converter de-rate and shut down exactly when load peaks.
Battery Life, Replacement and Costs
On urban delivery an i5 usually needs an auxiliary battery at two to three years; a converter normally lasts beyond 300,000 km if its cooling path stays clear. The indicative USD prices below suit stock planning.
| Part | Indicative USD price | Typical replacement point | Notes |
|---|---|---|---|
| DC-DC converter, 2.5-3 kW class | 420-650 | Fault-based, 300,000 km typical | Confirm part number against vehicle build |
| Auxiliary battery, pair of 12 V | 170-260 per pair | 2-3 years urban duty | Replace as a matched pair, never one cell |
| 24 V main fuse and holder | 25-45 | On any 24 V short circuit | Carry two on the service vehicle |
| Battery terminal set | 12-22 | Every battery change | Torque per manual, grease lightly |
| Converter cooling fan | 35-60 | If audible bearing noise | Replace rather than repair |
| Ground strap, chassis to 24 V rail | 18-30 | On any corrosion finding | Clean and bright both mating faces |
Never fit a larger auxiliary battery to compensate for a failing converter. A bigger battery hides the voltage sag for a few days longer and then fails too, having masked the actual fault. Fix the converter, keep the battery at the rating that matches the vehicle design, and the auxiliary system will behave predictably for years.
Charging Behaviour at Depots and the Sleep Cycle
Fleet depots with overnight AC charging should treat the auxiliary system as part of the charging routine, not as an afterthought. During a charge session the converter normally runs and tops the 24 volt battery, but only if the vehicle controller requests it. A truck that charges reliably but presents a flat auxiliary battery every morning has either a converter that is not being commanded on during charge, or an AC-DC control path fault that has nothing to do with the battery.
Fleets running mixed diesel and electric fleets often find that the technician's reflex, which is to fit a fresh battery and send the truck out, is exactly the wrong habit on an i5. Train the workshop on the sequence: codes first, rail voltage second, load test third, converter fourth, battery last. A truck returned to service with a healthy converter and an old but serviceable battery will keep running, while a truck with a new battery and a failing converter will be back within a week.
Buyers expanding into electric urban distribution can compare the i5 with the heavier i9 on the SAGMOTO new energy electric trucks range page, where traction battery size and converter rating differ. Matching the auxiliary load budget to the vehicle at specification stage avoids most of the load-related converter faults seen in service, and it is far cheaper than retrofitting capacity later.
The 24 volt system on an electric truck is small, cheap in parts and disproportionately important. It is the nervous system of a vehicle that otherwise has a large and expensive energy store. Twenty minutes of measurement at each service is enough to keep it reliable, and the discipline of diagnosing in order rather than replacing parts in hope is the real maintenance interval that matters.